Experience with cable-pulling studies
LCA prepares project-specific pulling calculations, reviews installation alternatives and coordinates thermal analysis where required. These representative projects reflect the scope of the engineering work performed.
Browse the project list below.
IAD 159
Thermal analysis and pulling studies.
IAD 327
Thermal analysis and pulling studies.
IAD 457 / ACB
Thermal analysis and pulling studies.
IAD 458
Cable-pulling tension study.
IAD 557
Thermal analysis and pulling calculations.
SJC02 — Prime Electric
Thermal analysis and pulling studies.
IAD 157
Thermal analysis and pulling calculations.
IAD 158
Thermal analysis and pulling calculations.
IAD 605
Thermal analysis and pulling calculations.
IAD 245 — Buildings A/B/D
Splice-box cable-pulling calculations.
IAD 203
Cable-pulling tension calculations.
IAD 230
Thermal analysis and pulling calculations.
BWI 150
Medium-voltage cable-pulling calculations.
IAD 501
Assumption-based cable-pulling engineering evaluation. Preliminary report; not a construction release.
IAD 450
Cable-pulling calculation submittal review.
Pulling-tension calculation project list
Additional detail on LCA’s pulling work, including older studies, preliminary engineering evaluations and calculation reviews.
| Project | Engineering scope |
|---|---|
| IAD 157 | Thermal analysis and pulling calculations. |
| IAD 158 | Thermal analysis and pulling calculations. |
| IAD 203 | Cable-pulling tension calculations. |
| IAD 230 | Thermal analysis and pulling calculations. |
| IAD 245 — Buildings A/B/D | Splice-box cable-pulling calculations. |
| IAD 605 | Thermal analysis and pulling calculations. |
| BWI 150 | Medium-voltage cable-pulling calculations. |
| IAD 159 | Thermal analysis and pulling studies. |
| IAD 327 | Thermal analysis and pulling studies. |
| IAD 457 / ACB | Thermal analysis and pulling studies. |
| IAD 458 | Cable-pulling tension study. |
| IAD 557 | Thermal analysis and pulling calculations. |
| SJC02 — Prime Electric | Thermal analysis and pulling studies. |
| IAD 501 | Assumption-based cable-pulling engineering evaluation. Preliminary report; not a construction release. |
| IAD 450 | Thermal analysis; cable-pulling calculation submittal review. |
Other recorded pulling-study assignments
These entries identify recorded project scopes; they are not presented as independently verified final-report releases.
| Project | Engineering scope |
|---|---|
| IAD 459 | Pulling studies. |
| IAD 461 | Pulling studies. |
| IAD 170 | Pulling studies. |
Additional thermal and coordinated study experience — 53 project entries
This historical list identifies thermal and related study scopes. It does not imply that each project included cable-pulling calculations.
| Project | Engineering scope |
|---|---|
| IAD 350 | Neher–McGrath thermal analysis. |
| IAD 351 | Neher–McGrath thermal analysis. |
| IAD 537 | Neher–McGrath thermal analysis. |
| IAD 534 | Neher–McGrath thermal analysis. |
| Neher–McGrath thermal analysis. | |
| BWI | Thermal analysis. |
| Turner Data Center | Thermal analysis. |
| MOD 3 | Thermal analysis. |
| Alfa Tech | Thermal analysis. |
| EPI | Thermal / Neher–McGrath analysis. |
| Saludos | Neher–McGrath analysis. |
| Microsoft 4.0 | Neher–McGrath studies. |
| San Antonio Hospital | Neher–McGrath consulting. |
| City of Riverside | Neher–McGrath calculations. |
| Plaza Substation | Neher–McGrath analysis. |
| Gehrlicher | Neher–McGrath analysis. |
| GMB | Neher–McGrath calculations. |
| SGL | Neher–McGrath calculations. |
| Intel | Neher–McGrath analysis. |
| Yahoo | Neher–McGrath calculations. |
| APL Data Center / Phase 2 | Thermal / Neher–McGrath analysis. |
| Bloom | Duct-bank analysis. |
| IGC D — Holmes | Neher–McGrath studies. |
| Mauka Fit | Neher–McGrath calculations. |
| IGC B — Holmes | Neher–McGrath study. |
| HelpNet utility duct bank | Thermal analysis. |
| QTS Hillsboro | Neher–McGrath analysis. |
| RagingWire SV1 | Thermal analysis. |
| Verizon SAP Building Expansion | Neher–McGrath analysis. |
| QTS DEN1 | Neher–McGrath thermal analysis. |
| WE Electric | Thermal analysis. |
| Aligned SLC05 | Neher–McGrath study. |
| Pioneer HQLC3 | Neher–McGrath study. |
| South Dade Transit | Thermal analysis. |
| Aligned Energy IAD03 | Neher–McGrath study. |
| EdgeCore Mesa PH03 | Thermal analysis. |
| AWS PHL100 | Thermal analysis. |
| PT Arista | Thermal analysis. |
| UHS Palm Beach — Gerelco | Duct-bank thermal analysis. |
| EdgeCore Mesa PH02 | Thermal analysis. |
| GOR2-A — Dyna | Neher–McGrath calculations. |
| IAD550 | Neher–McGrath study. |
| Sabey SDC Building A | Neher–McGrath study. |
| PDX181 cablebus | Thermal analysis. |
| Flexential Hillsboro | Thermal analysis. |
| PDX246 | Underground derating analysis. |
| PDX245 | Thermal analysis. |
| IAD551 | Thermal analysis. |
| IAD552 | Thermal analysis. |
| IAD554 | Thermal analysis. |
| Centra Logistics — Bogle and Flint | Thermal analysis. |
| IAD870 | Thermal analysis. |
| IAD871 | Thermal analysis. |